Lincoln sp 125 plus problems - Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...

 
Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.. Catzilla

Lincoln SP 125 Plus. $500 ... Save. Save. Share. Details. Condition. Used - Good. It's a little dusty but it works great no problems at all and that's a good price ...Lincoln SP 125 Plus. $500 ... Save. Save. Share. Details. Condition. Used - Good. It's a little dusty but it works great no problems at all and that's a good price ...If you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusBasic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsBasic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.1994 lincoln town car. radio and power antenna don't work. fuses are good everything else works. what is the problem? ... lincoln sp 125 plus glowworm 30 cxi ...Welding Equipment; Cutting Equipment; Gear & Tools; Accessories; Welding Wire, Flux & Rods; Guns & Torches; Automated Welding & Cutting Systems; Training Equipment for EducatorsHello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. This item, Lincoln SP-125 Plus Mig Welder, is part of the auction: Town of Hamburg Hwy, NY #14317. Lincoln SP-125 Plus wire feed problem 11-01-2008, 06:59 PM. A good friend of mine was given an old SP-125 that wasn’t quite working right. He replaced the gun, but now that I’m back I’ve checked it out and here’s the issue.Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.I just bought a lincoln sp 125 for $200 I havent seen it yet my grandpa got it and he is on his way home now he says it is in very good condition. I know it will not weld much at all but I figure I can use it for small projects and tacking. Then when I get money I will get a mm210.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusTo start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. 33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric EquipmentIt works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsRick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.VEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!Lincoln Electric. $118.81 ) +Free Shipping. SKU: S24355-4. Quantity: Decrease Quantity: Increase Quantity: Only left in stock! Adding to cart… category.add_cart ...Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Hello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.Home › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Premium quality 100Amp replacement MIG gun stinger torch, 10-foot (3m) cable, fully compatible with Lincoln Magnum 100L (K530-5) Usually Lincoln Magnum 100L (K530-5) MIG gun can be found on SP-85, SP-100, SP-100I, SP-100T, SP-125 Plus, SP-130T, SP-135 Plus, SP-140I, SP-155, SP-170, SP-170I, SP-170T, SP-175 Plus, SP-175T, Handy MIG 170I, MIG Pak 10, MIG Pak 15, Pro 100, Pro 155, Pro-Core 100 ...Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.Wire welder feed, but no arc (spark) 10-20-2012, 08:43 PM. I have a millermatic 150 that I bought used a few years ago. It has been an amazing welder. I was welding the other day and in the middle of a bead, it stopped welding. I have had this happen before and waited to let it cool and continued on.It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.Welding Equipment. Lincoln SP-125 Plus Welder. Machine has not been used in 3 years. Worked when removed from service. buyer responsible to provide help to remove it. no loading dock. Request appointment at asset location to view previous to bidding. Visit site and verify condition before bidding.I had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option ...926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.A short stick of welding filler metal consisting of a core of bare electrode covered by chemical or metallic materials that provide shielding of the welding arc against the surrounding air. It also completes the electrical circuit, thereby creating the arc. (Also known as SMAW, or Stick Metal Arc Welding.)Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...CHANGING DRIVE ROLL The SP-100 Wire Feed Drive Roll (1 ) has two grooves; one for 0.023” – 0.025” (0,6 mm) solid steel electrode and the other for 0.030” (0,8 mm) solid and 0.035” (O,9 mm) flux-cored steel electrode. Page 28 9. Screw the gas diffuser onto the end of the gun tube and securely tighten. 10.Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusIf your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.

Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. . Wow wind

lincoln sp 125 plus problems

Nov 1, 2008 · I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two. Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.This item, Lincoln SP-125 Plus Mig Welder, is part of the auction: Town of Hamburg Hwy, NY #14317. Lincoln SP-125 Plus wire feed problem 11-01-2008, 06:59 PM. A good friend of mine was given an old SP-125 that wasn’t quite working right. He replaced the gun, but now that I’m back I’ve checked it out and here’s the issue.#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened.Your #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.Lincoln Electric is one of the world's largest manufacturers of industrial welding supplies, and WeldingMart is the largest online Lincoln welder parts dealer. We also carry a selection of parts from Miller Electric. Whether you're repairing an older welder or upgrading a new one, our high-quality welder parts and service will help make it happen.SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...#1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened..